Global innovator of pipeline safety equipment since 2006, serving over 120 countries with certified industrial valve solutions
The SSDJ-FZ-*F/C-RQZ gas safety shut-off valve represents a critical component in modern gas transmission and distribution systems. Designed with advanced pressure monitoring capabilities, this valve automatically activates upon detection of dangerous pressure fluctuations - including overpressure scenarios exceeding operational limits or sudden pressure loss events. Using a spring-loaded cutoff mechanism that requires manual reset after activation, it ensures failsafe operation in both industrial plants and pipeline infrastructures. The series includes multiple configurations adaptable to pipeline diameters ranging from 1" to 12", with pressure monitoring ranges adjustable from 0.5kPa to 100kPa. Constructed from ASTM A351 CF8M stainless steel bodies with NBR diaphragm seals, these valves provide superior corrosion resistance in demanding gas environments.
Continuous monitoring for overpressure and pressure loss events with ±1% accuracy
Requires deliberate operator intervention to ensure system integrity after cutoff events
316L stainless steel bodies withstand pressures up to 16 bar with temperature resistance from -20°C to +80°C
The global gas safety equipment market is projected to grow at 7.2% CAGR through 2030 (Global Gas Safety Association, 2023). This growth is driven by increased natural gas consumption, stringent safety regulations like EN 13611:2019 for automatic shut-off devices, and pipeline infrastructure expansions across developing economies. Modern cut-off valves increasingly incorporate digital monitoring capabilities - a technological frontier where the SSDJ-FZ-*F/C-RQZ platform provides versatile retrofitting options through its modular sensing compartment.
"Modern gas networks require intelligent shutdown solutions that integrate mechanical reliability with digital monitoring capabilities. The industry shift toward smart monitoring presents manufacturers with both engineering challenges and opportunities for innovation."
- Dr. Chen Wei, Pipeline Safety Monthly Journal
Parameter | Standard | Premium | High-Performance | Testing Standard |
---|---|---|---|---|
Nominal Diameter (DN) | 25mm - 100mm | 100mm - 200mm | 200mm - 300mm | EN 161:2023 |
Max Operating Pressure | 5 bar | 10 bar | 16 bar | ISO 5208:2022 |
Set Pressure Accuracy | ±2% | ±1.5% | ±1% | DIN 3381:2019 |
Temperature Range | -15°C to +70°C | -20°C to +80°C | -30°C to +100°C | ISO 6978:2022 |
Seal Material | NBR | HNBR | Viton | EN 549:2022 |
Actuation Time | ≤3 seconds | ≤2 seconds | ≤1.5 seconds | ISO 23553-1:2021 |
Fig. 1: Pressure Tolerance Across Valve Series
Fig. 2: Temperature Performance Comparison
The SSDJ-FZ-*F/C-RQZ gas safety shut-off valve provides critical protection in these environments:
City gate stations utilize these valves to isolate pipeline segments during pressure surge events, preventing widespread shutdowns. Overpressure protection at 1.15x normal operating pressure prevents cascade failures.
Furnace feed lines incorporate F/C-RQZ valves to prevent backflow incidents and downstream pressure losses. The manual reset function ensures deliberate safety verification before restarting operations.
Emergency shutdown systems combine these valves with gas detectors for comprehensive hazard management. Cryogenic-resistant variants maintain seal integrity down to -165°C during LNG transfer operations.
Data source: Petrochemical Infrastructure Safety Council, 2023 Report
These valves are certified to EN 161:2023 (Automatic shut-off devices for gas supply), ISO 23553-1:2021 (Safety and control devices), and ATEX Directive 2014/34/EU for explosive environments. Materials certifications include PED 2014/68/EU for pressure equipment.
With proper maintenance cycles, the standard NBR-sealed version has a 10-year service life in natural gas environments at temperatures below 70°C. The Viton-sealed HP series extends this to 15 years in aggressive gas mixtures including those containing H₂S.
The manual reset function ensures that after any cutoff event, engineers must physically inspect the system, diagnose the pressure anomaly cause, and deliberately reset the valve. This prevents automatic system restarts without safety verification.
This platform supports piezoelectric, strain gauge, and capacitive pressure sensors through its standardized sensing chamber. Popular options include the DIN-compliant G1/4" sensor modules with 4-20mA output or Modbus RTU communication protocols.
Yes, OUYINUO provides flange adapter kits for retrofitting existing gate valves. The compact F/C-RQZ actuator module mounts vertically to valve stems with torque ratings up to 250Nm.
Annual procedures include: (1) Full-cycle valve actuation test, (2) Diaphragm integrity inspection, (3) Sensor calibration verification, and (4) Seal replacement every 5 years or 2,000 actuation cycles (whichever comes first).
Three redundancy measures are implemented: (1) Secondary spring-loaded locking mechanism, (2) Independent overtravel prevention stops, and (3) Burst-proof diaphragm design certified to 5x max operating pressure.
For custom configurations or volume quotations, contact OUYINUO engineering team