With the change of China's energy structure and the constant increase of environmental protection, the natural gas develops rapidly in development and utilization. After purifying and compressing the natural gas from the wellhead or pipeline, the CNG is stored and transported at high pressure to the place of use, and decompressed and directly delivered to the pipeline network through multi-stage heat exchange to supply various users.
The range of 300km between the CNG station and the place of use is economic, no more than 500km generally, with a supply scale of 2,000-4,000 households. The air supply of 200-5,000Nm3/h is appropriate. Too large or too small air supply will increase the unit gas costs.
The long-distance pipeline of this system has small investment scale, short construction period and quick payback. It can be served as the peak load and emergency gas sources of the long-distance pipeline in future.
Working principle of CNG station: Preheat the high pressure natural gas in the pry tank, depressurize gradually, and perform working procedures such as safety control, metering and deodorization to make the gas reach the pressure conforming to the specification requirements, then deliver to the pipeline.
The CNG station can be divided into two-staged pressure regulation and three-staged pressure regulation according to the pressure regulation mechanism.
According to the layout in the equipment station and the equipment function, the CNG station includes: Unloading system (high pressure hose, quick coupler and high-pressure valve), pressure regulating heat exchange system (high pressure emergency cutoff valve, heat exchanger, pressure regulator and relief valve), flow metering system (flowmeter), control system (central console) and heating system (gas boiler, hot water pump, etc.).
The natural gas in the pry car enters the pressure regulating heat exchange system via the unloading system for 2 heat exchanges, then enters the flow metering and odorization systems through 2 or 3 pressure regulations, then enters the pipeline network. The heating system provides the heat required for the gas pressure reducing process, and the control system monitors the whole system.
Model |
CNG-300 |
CNG-500 |
CNG-1000 |
CNG-2000 |
CNG-2000 |
CNG-3000 |
CNG-4000 |
CNG-5000 |
|
Hourly Maximum Flow Rate (Nm³/h) |
300 |
500 |
1000 |
2000 |
2000 |
3000 |
4000 |
5000 |
|
Structure Form |
One for use and one for backup |
||||||||
Pressure Regulation Level |
Secondary pressure regulation |
Third pressure regulation |
|||||||
Inlet Temperature (°C) |
65-85 |
65-85 |
65-85 |
65-85 |
65-85 |
65-85 |
65-85 |
65-85 |
|
Primary Heat Exchange Return Water Temperature (°C) |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
|
Secondary Heat Exchange Return Water Temperature (°C) |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
|
Outlet Gas Temperature (°C) |
10-20 |
10-20 |
10-20 |
10-20 |
10-20 |
10-20 |
10-20 |
10-20 |
|
(Mpa) Primary Post-regulation Gas Pressure (Mpa) |
1.0-6.0 |
1.0-6.0 |
2.0~ 6.0 |
2.0-6.0 |
3.0~ 7.5 |
3.0-7.5 |
3.0~ 7.5 |
3.0-7.5 |
|
Secondary Post-regulation Gas Pressure (Mpa) |
0.1 ~0.4 |
0.1-0.4 |
0.1-0.4 |
0.1-0.4 |
1.6-2.5 |
1.6-2.5 |
1.6-2.5 |
1.6-2.5 |
|
Third Post-regulation Gas Pressure (Mpa) |
- |
- |
- |
- |
0.1-0.4 |
0.1-0.4 |
0.1-0.4 |
0.1-0.4 |
|
Outlet Gas Pressure (Mpa) |
0.1-0.4 |
0.1-0.4 |
0.1-0.4 |
0.1-0.4 |
0.1-0.4 |
0.1-0.4 |
0.1-0.4 |
0.1-0.4 |
|
Primary Release Pressure (Mpa) |
1.3 ~ 7.8 |
1.3 ~ 7.8 |
2.6 ~ 7.8 |
2.6 ~ 7.8 |
3.9-9.75 |
3.9- 9.75 |
3.9-9.75 |
3.9- 9.75 |
|
Secondary Release Pressure (Mpa) |
0.13-0.52 |
0.13-0.52 |
0.13-0.52 |
0.13-0.52 |
2.08-3.25 |
2.08-3.25 |
2.08-3.25 |
2.08-3.25 |
|
Third Release Pressure (Mpa) |
- |
- |
- |
- |
0.13 - 0.52 |
0.13 - 0.52 |
0.13 - 0.52 |
0.13 - 0.52 |
|
Inlet Diameter |
DN25 |
DN25 |
DN25 |
DN40 |
DN40 |
DN50 |
DN50 |
DN50 |
|
Outlet Diameter |
DN50 |
DN80 |
DN100 |
DN100 |
DN100 |
DN150 |
DN150 |
DN150 |
|
Dimensions (m) |
6.5x2x2.3 |
6.5x2x2.3 |
6.5x2x2.3 |
6.5x2x2.3 |
6.5x2x2.3 |
6.5x2x2.3 |
6.5x2x2.3 |
6.5x2x2.3 |
|
Weight (t) |
2.6 |
2.7 |
2.8 |
3 |
3.5 |
4 |
4.3 |
4.6 |
|
Optional Boiler Power (Large Calorie) |
2.0
|
2.5
|
5
|
10
|
10
|
15
|
20
|
25 |